36V in-amp family for AI modules, weighing, transmitters, DAQ: COS620/128/129/8221

Jarwey 1 2026-09-03 10:27:32

COSINE’s catalog lists 36V instrumentation amplifiers for: analog input modules, weighing scales, temperature transmitters, pressure transmitters, data acquisition (DAQ), and lab/field instruments. These jobs usually mean ±15 V / wide common-mode, external Rg for gain, and second-source evaluation versus INA128 / INA129 / AD620 / AD8221—not the same rail or mechanical constraints as 5V portable in-amps (COSINA333 family).

Metrics follow the 2025 catalog (gain 1–10000; see catalog for gain equations). Request datasheets from Jarwey; qualify before production. For ECG/EEG front-end detail see the earlier COS620 article—this page stays on industrial DAQ / weighing / transmitter selection.

Product features

High precision, low drift, low noise density; ~4.5–36 V (±2.25–±18); external Rg sets gain.

Applications (vendor-stated)

Analog input modules · weighing scales · temperature transmitters · pressure transmitters · DAQ · lab and field instruments.

36V instrumentation amplifier table

PN Supply (V) Gain Gain formula BW Noise @1kHz Vos / drift Iq Cross-ref Page
COS620BRZ 4.5~36 (±2.25~±18) 1~10000 1+49.4kΩ/Rg 1.5 MHz 8 nV/√Hz 50 µV / 0.7 µV/°C 1.3 mA INA129 / AD620 864
COS620ARZ 4.5~36 (±2.25~±18) 1~10000 1+49.4kΩ/Rg 1.5 MHz 8 nV/√Hz 50 µV / 0.7 µV/°C 1.3 mA INA129 / AD620 918
COS128U 4.5~36 (±2.25~±18) 1~10000 1+50kΩ/Rg 1.5 MHz 8 nV/√Hz 50 µV / 0.7 µV/°C 1.3 mA INA128 919
COS129U 4.5~36 (±2.25~±18) 1~10000 1+49.4kΩ/Rg 1.5 MHz 8 nV/√Hz 50 µV / 0.7 µV/°C 1.3 mA INA129 / AD620 920
COS8221ARZ 4.5~36 (±2.25~±18) 1~10000 1+49.4kΩ/Rg 1.5 MHz 8 nV/√Hz 50 µV / 0.7 µV/°C 1.3 mA AD8221 921

For portable 5V / battery weighing domains, see 5V instrumentation amplifiers (COSINA333).

Checklist mapped to vendor applications

  1. Analog input / DAQ: common-mode, input protection, and 4.5–36 V supply aligned?
  2. Weighing: bridge excitation & resolution vs 50 µV Vos / 0.7 µV/°C; Rg calibration repeatable?
  3. Temp / pressure transmitters: field common-mode, cable noise, CMRR/filter plan.
  4. Lab / field instruments: do you truly need gain to 10000? noise & stability at high gain.
  5. Cross-ref split: INA128→COS128; INA129/AD620→COS620/COS129; AD8221→COS8221 (verify—not drop-in).
  6. Grade / suffix: ARZ/BRZ/U match temp grade and AVL.
  7. Samples: request datasheets and pilot qty from Jarwey before primary change.

Pages & contact

Send incumbent INA128 / INA129 / AD620 / AD8221 PNs and module type (AI / weighing / transmitter / DAQ) to Jarwey: kerry.w@jarwey.cn · Contact.

Previous: Select COS228-family 36V 25MHz precision op-amps: 1/2/4-ch checklist
Related Articles